Five core categories covering power, control, safety, and network cabling — use the filters below to search by category, size, or voltage, or browse every category directly.

A. Low-Voltage Power Cables — PVC Insulated

For residential, commercial & industrial lighting and power
Request a Quote

PVC-insulated cables with solid or stranded (“majdoul”) copper conductors, available at two standard voltage ratings.

Voltage
300/500V & 450/750V
Conductor
Copper (solid / stranded)
Packaging
Coils of 100m

Single-Core Sizes (mm²)

0.5 mm²0.75 mm²1 mm²1.5 mm²
2 mm²2.5 mm²3 mm²4 mm²
6 mm²10 mm²16 mm²25 mm²
35 mm²50 mm²70 mm²95 mm²
120 mm²150 mm²185 mm²240 mm²
300 mm²

Multi-core sizes: 2×1 through 4×35 mm² (standard), plus armored sizes from 3X50+25 up to 3X300+150 mm².

B. Control Cables (Copper)

For control & instrumentation circuits
Request a Quote

Multi-core copper control cables rated 300/500V, for panel and control-circuit wiring.

Voltage
300/500V
Conductor
Copper

Available Sizes (mm²)

5×1 mm²7×1 mm²12×1 mm²
5×1.5 mm²7×1.5 mm²12×1.5 mm²

C. Fire-Alarm Cables

Shielded or unshielded
Request a Quote

Cables engineered for high operating temperatures, for fire detection & alarm systems.

Operating Temperature
105°C
Voltage
500V
Shielding
Optional (shielded / unshielded)

Available Sizes (mm²)

2×1 mm²2×1.5 mm²2×2 mm²2×2.5 mm²

D. Stranded Aluminum Tape Cable

PVC insulated & sheathed
Request a Quote

Stranded aluminum tape cable for wider-scale power distribution, an economical option for larger projects.

Voltage
0.6/1KV
Insulation & Sheath
AL/XLPE/STA/PVC
CU/XLPE/STA/PVC

Available Sizes (mm²)

4×16 mm²4×25 mm²4×35 mm²
3X50+25 mm²3X70+35 mm²3X95+50 mm²
3X120+70 mm²3X150+70 mm²3X185+95 mm²
3X240+120 mm²3X300+150 mm²

E. Telephone Cables

For data & telecom wiring
Request a Quote

Two lines: CAT5/CAT6 telephone cables in 305m coils, and ‘thermo’ telephone cables with tinned-copper conductors.

CAT5/CAT6 Telephone Cables (305m/coil)

CAT5 UTPCAT6 UTP

Telephone Cables (pairs)

1×2×0.6 — 250×2×0.6 mm²

PVC insulated & sheathed, tinned-copper conductors.

Residential Sizing Guide

Which Cable Size Do You Need?

A quick reference for homeowners and electricians choosing the right size — confirm with a qualified engineer for final sizing.

SizeTypical Use
1 mm²Lighting circuits — up to nine 9W bulbs per line (≈450W total)
1.5 mm²Standard room sockets (10–14A)
2 mm²Kitchen/heavy appliance sockets — washing machine, fridge, freezer
3 mm²Kitchen appliances + air conditioners (2.25–2.5 HP)
4 mm²Air conditioners (higher-capacity circuits)
6 mm²Instant water heaters; A/C units 3 HP and above
10 mm²Riser cable, meter-to-apartment, units up to ≈70–120 m²
16 mm²Riser cable, meter-to-apartment, smaller units under 70 m² (heavier load)

Need Pricing?

Prices change with the market and are VAT-dependent, so contact us directly for an up-to-date quote.